Aluminium Fire-Rated Doors Dubai

Aluminium fire-rated doors, walls, partitions, and curtain wall for UAE projects. Aluprof EI 15 to EI 120 systems — tested to UK and European standards, certified by IFT Rosenheim, ITB, and ATG.

Fire-rated aluminium internal screen with door in an office environment

Fire-rated aluminium doors and screens are a compliance requirement on almost every multi-storey project in the UAE — and getting them right is the difference between Civil Defence sign-off on first inspection and a costly hold-up before handover. London Architectural Aluminium fabricates fire-rated aluminium systems from our Al Qusais facility across the full EI 15 to EI 120 range, using Aluprof’s fire-rated range. Browse the systems we work with below, organised by application.

Fire-rated systems we fabricate

Aluprof fire-rated systems organised by application. Each tile opens a quote request pre-set for that system.

Best for Doors

Stairwell enclosures, lift lobbies, cross-corridor compartmentation, and protected egress. EI 15 to EI 90 in a single profile family.

Aluprof MB-78EI fire-rated aluminium door 3D render

Aluprof MB-78EI

Aluprof

Most-specified Aluprof fire door in UAE buildings. Stairwell enclosures, lift lobbies, cross-corridor break points. Single + double leaf.

EI Rating
EI 15-90
Profile
78 mm
Learn more →
Aluminium glazed fire-rated door with panic push bar

Aluprof MB-78EI DPA

Aluprof

Panic-exit variant of MB-78EI — EN 1125 push-bar / touch-bar hardware compatible. Fire-exit doors at stairwell discharge and emergency egress.

EI Rating
EI 15-60
Hardware
EN 1125 panic
Learn more →
Fire-rated aluminium doors at a commercial building floor

Aluprof MB-86 EI

Aluprof

For projects already specifying the MB-86 thermal door elsewhere — gives visual continuity between fire and non-fire openings on the same elevation.

EI Rating
EI 30-60
Profile
86 mm
Learn more →

Best for Internal Partitions & Walls

Walls, screens, integrated wall+door assemblies. EI 30 to EI 120 — for stairwell enclosures, refuge floors, plant-room compartmentation, and office fire zoning.

Aluprof MB-118EI fire-rated aluminium wall system 3D render

Aluprof MB-118EI

Aluprof

Flagship 118 mm wall system. Heaviest rating in the line-up — used for refuge floors, fire-fighting cores, plant rooms, and stairwell enclosures on taller buildings.

EI Rating
EI 30-120
Profile
118 mm
Learn more →
Fire-rated aluminium partition with door in office

Aluprof MB-78EI Partitions

Aluprof

Same MB-78EI profile in door-less, glazed-only partition configurations. Office compartmentation, cross-corridor screens, lobby separations.

EI Rating
EI 15-90
Profile
78 mm
Learn more →

Best for Curtain Wall

Fire-rated façade compartmentation — between adjoining buildings, atrium edges, floor-to-floor spandrels, and cross-block boundaries.

Aluprof MB-SR50N EI fire-rated curtain wall on a commercial facade

Aluprof MB-SR50N EI

Aluprof

Stick-system fire-rated curtain wall. The right choice for façade fire compartmentation between adjoining buildings or between floors.

EI Rating
EI 30 / EI 60
Sightline
50 mm
Learn more →
Aluprof MB-SR50N EI EFEKT structurally-glazed fire-rated curtain wall

Aluprof MB-SR50N EI EFEKT

Aluprof

Structurally-glazed (silicone-jointed) variant — no exposed pressure plates on the visible elevation. Cleanest façade sightlines with the EI rating intact.

EI Rating
EI 30 / EI 60
Glazing
Structural silicone
Learn more →

Where fire-rated aluminium glazing is required in UAE buildings

Dubai Civil Defence and the Abu Dhabi DMT enforce specific fire compartmentation requirements on multi-storey projects. The systems above typically sit at:

Stairwell enclosures + lift lobbiesEI 60 / EI 90 — protected egress routes during an incident
Cross-corridor compartmentationEI 30 / EI 60 — break points required by the building’s fire strategy
Plant rooms + electrical risersEI 60 – EI 120 — high-risk areas, classification per fire consultant
Fire-rated curtain wallEI 30 / EI 60 — façade fire compartments, between-building boundaries
Fire-rated entrance screensEI 30 / EI 60 — at the building boundary for hospitality + commercial fit-outs

EI ratings in plain language

EI ratings come from EN 13501-2 and combine two performance criteria. The number after EI is the rated minutes.

E — IntegrityHow long the assembly resists flame penetration
I — InsulationHow long it limits heat transfer to the unexposed side
EI 3030 minutes of both integrity + insulation
EI 6060 minutes (1 hour) — typical for mid-rise compartmentation
EI 9090 minutes — typical for stairwell enclosures on taller buildings
EI 120120 minutes (2 hours) — refuge floors, plant rooms, fire-fighting cores

Certification, testing and Dubai Civil Defence approval

Fire classification is only meaningful when it names the standard it was tested to, and the approval route it satisfies in the UAE.

Every EI classification we quote is issued against EN 1634-1, the European test method for fire resistance of door, shutter and openable window assemblies, with the resulting performance classified to EN 13501-2. Where a project specification is written to the British or American route instead, the equivalent references are BS 476 Part 22 and UL 10C — a fire consultant will confirm which applies to your building.

In Dubai, the governing document is the UAE Fire and Life Safety Code of Practice, administered by Dubai Civil Defence (DCD). Fire-rated aluminium glazing must be supplied with its approval documentation, and we issue the full pack with every order: the DCD-approved product listing, the certified test report for the tested assembly, the fire door identification label, and the installation and maintenance record required under NFPA 80.

One point worth understanding before you specify: fire certification belongs to a complete tested assembly — profile, glass, intumescent seals, gaskets, hardware and fixings as one system. Substituting any component invalidates the certificate. That is why we fabricate to the tested configuration rather than assembling equivalents.

EI rating by application — and the system we fabricate for it

A practical map from the classification on your drawings to the Aluprof system that achieves it.

Fire-rated aluminium glazing: classification, application and system. Final classification is always set by the project fire strategy.
ClassificationPerformanceTypical application in UAE buildingsSystem we fabricate
EI 3030 min integrity + insulationApartment entrance doors, corridor screens, fire-rated shopfronts and entrance screens, façade compartmentationAluprof MB-78EI, MB-SR50N EI (curtain wall)
EI 6060 min integrity + insulationStairwell and lobby enclosures, mid-rise compartmentation, between-building boundaries, hospitality fit-out screensAluprof MB-78EI, MB-86EI, MB-SR50N EI
EI 9090 min integrity + insulationStairwell enclosures on taller towers, protected escape routes where the fire strategy calls for extended protectionAluprof MB-118EI
EI 120120 min integrity + insulationRefuge floors, fire-fighting cores, plant rooms, electrical risers, high-risk separationsAluprof MB-118EI

Where escape doors need panic hardware, we fit hardware certified to EN 1125 on the tested assembly. For fire-rated façades and atrium edges, MB-SR50N EI carries the classification through the curtain wall itself rather than relying on a separate screen behind it.

Local fabrication advantage

Fire-rated certification is granted to a complete tested assembly — profile, glass, gasket, intumescent, hardware, and connections all together. Imported finished fire doors are delivered as a fixed-size product; modifying them on site invalidates the test certificate.

Local fabrication at our Al Qusais facility lets us size doors, walls, and curtain wall to the actual opening on architect drawings while staying within the Aluprof tested specification. The documentary chain — test report, manufacturer’s certificate, installer’s statement of conformity — remains intact end-to-end.

Aluprof publishes test reports from IFT Rosenheim (Germany), ITB (Poland), and ATG (Belgium) covering EN 13501-2 (fire classification) and EN 1191 (self-closing). UAE consultants demonstrating Civil Defence compliance use this exact documentary chain.

Frequently Asked Questions

Common questions about fire-rated aluminium systems on UAE projects.

EI ratings come from EN 13501-2. The number is the rated minutes the assembly maintains both Integrity (E — resistance to flame penetration) and Insulation (I — heat transfer to the unexposed side). EI 30 holds for 30 minutes; EI 120 holds for 2 hours. UAE consultants typically specify EI 30 or EI 60 for cross-corridor compartmentation, EI 90 for stairwell enclosures on taller buildings, and EI 120 for refuge floors and plant rooms.

Aluprof fire-rated systems are tested and certified to European standards (EN 13501-2 fire classification, EN 1191 self-closing performance) with assembly audits by IFT Rosenheim, ITB, and ATG. UAE Civil Defence accepts the European certification chain on the consultant’s documentary submission, alongside the local installer’s statement of conformity that the assembly was fabricated to the tested specification.

Yes. Fire-rated certification is granted to a complete tested assembly, so fabrication must follow the manufacturer’s tested specification exactly. Local fabrication at our Al Qusais facility lets us size doors to the actual opening on architect drawings without invalidating certification — something not possible with imported fixed-size finished doors.

Dubai Civil Defence and Abu Dhabi DMT enforce fire compartmentation at stairwell enclosures (typically EI 60 or EI 90), lift lobbies, cross-corridor break points (EI 30 or EI 60), plant rooms and electrical risers (EI 60 to EI 120), fire-rated façades where adjoining buildings share a boundary, and entrance screens on certain hospitality and commercial fit-outs.

Yes. Aluprof fire-rated systems are tested to EN 13501-2 (fire classification) and EN 1191 (self-closing), with assembly audits by IFT Rosenheim (Germany), ITB (Poland), and ATG (Belgium). Architects who have specified Aluprof on UK or European projects can carry the same approval package across to UAE projects.

Lead times vary by project size and specification, but local fabrication at our Al Qusais facility means shorter lead times than importing finished fire-rated doors from Europe. We can confirm a lead time on receipt of architect drawings, the fire strategy document, and the door / wall schedule.

Our EI classifications are tested to EN 1634-1, the European test method for fire resistance of door and openable window assemblies, and classified to EN 13501-2. Where a specification is written to the British or American route, the equivalent references are BS 476 Part 22 and UL 10C. We supply the certified test report for the tested assembly with every order.

Every fire-rated order ships with the DCD-approved product listing, the certified test report, the fire door identification label, and the installation and maintenance record required under NFPA 80. These are the documents Dubai Civil Defence expects at inspection under the UAE Fire and Life Safety Code of Practice.

Not sure which system is right for your project?

Send us your drawings, fire strategy document, or door schedule. We’ll recommend the right Aluprof fire-rated system, EI rating per opening, and lead time — quote returned in AED within 48 hours.